If it's getting hot, manually boost the fan speeds, or allow TG Pro to do it automatically to help keep the Mac cool and running fast. Get local or email notifications for temperature events along with full logging for further analysis. It's designed with security in mind. TG Pro is notarized and uses the Hardened Runtime.
Maximum current - amps - through a 12V circuit - related to size (AWG) and length of wire
Conductors in electrical systems should not be sized with voltage drops exceeding 3%.
2 0 Gauge Wire
For a 12V system the maximum voltage drop should be less than (12 V) x 3% = 0.36 V.
Conductor sizes (AWG) related to maximum current through a 12V electrical wire and length of cable - are indicated below:
| American Wire Gauge (#AWG) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Length (feet) | Maximum Current (amps) | |||||||||
| 5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 70 | |
| 15 | 16 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 4 | 4 |
| 20 | 14 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 |
| 25 | 14 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 2 | 2 |
| 30 | 12 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 |
| 40 | 12 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1/0 |
| 50 | 10 | 8 | 6 | 4 | 4 | 2 | 2 | 1 | 1/0 | 1/0 |
| 60 | 10 | 6 | 6 | 4 | 2 | 2 | 1 | 1/0 | 2/0 | 2/0 |
| 70 | 10 | 6 | 4 | 2 | 2 | 2 | 1/0 | 2/0 | 2/0 | 3/0 |
| 80 | 8 | 6 | 4 | 2 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 |
| 90 | 8 | 4 | 4 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 |
Note! Failure to use an adequate size may result in a fire. Always secure electric wires with fuses.
- 1 ft (foot) = 0.3048 m

Wire Gauge Design Procedure

- calculate total length of wire from source to device and back again
- determine amount of current in wire
- determine correct wire gauge in the intersection of amps and feet
Note! Wire size based on 3% (0.36 V) voltage drop in a 12 Volt circuit. Always oversize wires if voltage drop is critical.
print 12V Cable Length Diagram
Example - 12 V Cable and Maximum Length and Current
The maximum current in a 12 Vgauge #6 (13.3 mm2) cable with length 15 m is approximately 15 amps according the diagram above.
2 0 2 0 1 Aluminum Wire
The maximum current in a gauge #10(5.26 mm2) cable with length 15 m is approximately 5 amps.
Related Topics
- Electrical - Electrical units, amps and electrical wiring, wire gauge and AWG, electrical formulas and motors
Related Documents
- 12 Volt Current and Maximum Wire Length - Maximum copper wire length with 2% voltage drop
- AWG - American Wire Gauge and Circular Mils - AWG, diameter mil, circular mil, diameter in mm and area in mm2
- AWG Wire Gauges Current Ratings - Common US AWG wire gauges and amps ratings
- BWG - Birmingham Wire Gauge - Used to determine wall thickness of pipe - in gauge and decimal parts of inch
- Electric Cable Installations - Current Rating - Current ratings and cable sizes for fixed installations within buildings
- Electric Circuit Diagram - Template - Use Google Drive to make online shareable electric circuit diagrams
- Electric Wire Resistance for Various Materials - Copper, Aluminum, Brass, Constantan, Nichrome, Platinum, Silver and Tungsten
- Electrical Motor Power and Maximum Cable Length - Maximum cable lengths for electrical motors
- Lead Acid Batteries - Specific gravity and charge of lead acid batteries - temperature and efficiency
- SWG - Standard Wire Gauge - Imperial Standard Wire Gauge used for sheet metal and wire
- Wire - Convert from Square mm to Diameter mm - Convert from square mm to diameter mm
- Wire Gauge Converter - AWG versus square mm - American Wire Gauge (AWG) versus square mm cross sectional area
Tag Search
Istat Pro
- en: amps wire gauge current length AWG
- es: amperios calibre del cable longitud actual AWG
- de: Verst채rker Drahtst채rke aktuelle L채nge AWG
2 0 Gauge Cable
Temperature Gauge Pro 2.33 | Mac OS X | 8 MB.
TG Pro is an essential utility for all Mac users with three main features:
• Check up on your Mac by viewing current and maximum temperatures recorded by each sensor. Choose between degrees Celsius or Fahrenheit.
• Tune the fan speed so your Mac can run cooler with manual fan control. Or is it the fans rotate at maximum speed automatic Boost when a specific temperature is reached.
• Discover defective fans and temperature sensors with integrated diagnostics.
Temperature Gauge Pro will also display a notification through the Notification Center or Growl when the temperature is hit or automatic Boost is enabled. Also, you enter all the information into a CSV file to graph in an external application. It works on all Macs, either a laptop or desktop computer.
Temperature Gauge Pro 2.0.2 Tool
Thursday January 01, 1970
Comments are closed.